Components for
gas supply systems |
The pressure regulator ET 200 reduces an inlet pressure of max. 40 bar down to an outlet pressure and maintains it constant as far as possible.
|
Application:
· For all pressure regulating duties within the stated working ranges with a high accuracy in the control of the outlet pressure.
· All gases to which the materials used are resistant, e.g. compressed air, oxygen, nitrogen, carbon dioxide, forming gas, acetylene, propane, butane, hydrogen, fuel gases, town gas, methane, rare gases.
Quality:
· TORNADO – fittings guarantee superior quality. This is achieved through the use of high grade materials and a quality assurance program conforming to DIN ISO 9001. All system components which come in contact with the medium are made free of oil and grease.
· TORNADO – fittings undergo 100% leakage and function testing.
Advantages:
· Compact design
· Low weight
· Outlet pressure limitation by a mechanical locking
· Central filter
|
Technical data: |
TORNADO ET 2000 |
|
Inlet Pressure PV: max. 40 bar |
|
max. 1,5 bar (acetylen) |
|
Outlet Pressure PH: 1,5-20 bar |
|
|
|
Materials: |
|
Body and pressure regulator cover: brass |
|
Diaphragm: EPDM |
|
Valve cone: EPDM |
|
|
|
Weight: 1,3 kg |
|
|
|
Connections: |
|
Inlet: ¼” npt |
|
Outlet: G 3/8” RH |
|
G 3/8” LH (fuel gas) |
Flow Rates:
|
Acetylen
Inlet pressure
[bar] |
Flow rate [m³/h]
At an outlet pressure [bar] |
|
0,3 |
0,5 |
1 |
|
1,3 |
0,2 |
0,5 |
1 |
|
Oxygen
Inlet pressure
[bar] |
Flow rate [m³/h]
At an outlet pressure [bar] |
|
0,3 |
0,5 |
3 |
|
10
20
25
40 |
2
2
2
- |
5
5
5
5 |
12
15
15
15 |
|
[bar] 6 |
10 |
20 |
|
10 15
20 20
25 20
40 20 |
-
25
30
40 |
-
-
45
50 |
Dimensions:

|